Cleaning method and mechanism of a submerged membrane bioreactor for a long-term operation

Fu Wei,Wang Zhiwei,Yin Xing,Wang Pan,Wang Qiaoying,Wang Xu
DOI: https://doi.org/10.3969/j.issn.1002-8471.2009.z2.046
2009-01-01
Abstract:In order to investigate the fouling reasons and cleaning methods of a submerged membrane bioreactor for more than 2 years operation,SEM-EDS,FTIR and contact angle system,were applied to analyze the membrane fouling layer.The cleaning effects of membrane by different cleaning methods were studied and the fouling process was also suggested.The result showed that the cleaning effects of membrane by acid cleaning were good and acid cleaning could remove most of inorganic foulants,but could not effectively remove organic foulants such as organic acid,protein and polysaccharide.While,the cleaning effects of membrane by NaOH and NaClO were not very good because the influent of MBR was effluent of coagulation-sedimentation tanks.With membrane running lastingly,the membrane foulants were almost inorganic foulants,and inorganic and organic foulants were complex by the chelate effect of organic foulants,so it was very difficult for alkali and oxidant to remove organic foulants.
What problem does this paper attempt to address?