Simulation Analysis of Temperature Control of Pier Pile Cap in Construction Period

Chen Junsheng,Cao Hong,Mo Haihong
DOI: https://doi.org/10.19731/j.gdtmyjz.2011.12.016
2011-01-01
Abstract:3D FEM is used to analyze temperature field of mass concrete of pile cap.The analysis considered thecooling pipes and external environment.The analysis results indicate position of maximum temperature gradient locates on surface of pile cap.Increasing the pour interval of concrete is a better way to reduce the interaction of heat of hydration between different layer of concrete.The effect of external environment on core temperature of pile cap concrete is small,but external environment evidently affects the surface stress of pile cap concrete.
What problem does this paper attempt to address?