On the factors influencing COD removal in pigsty sewage by UASB
YAN Li-long,WANG Xiao-hui,LIANG Hai-jing,LIU Yu,REN Yuan
DOI: https://doi.org/10.3969/j.issn.1009-6094.2013.03.015
2013-01-01
Abstract:The paper is inclined to present the results of our study of the factors influencing COD removal in the pigsty sewage byUASB in hoping to reduce the pollution caused by the organic matters in livestock sewage. Forthis purpose, we have chosen a smal-l scale exper-i mental device of UASB. To be exact, we have investigated all the likely influential factors in this way, such as the volume load, pH value, temperature and reflux ratio, underthe conditions of the inflow COD between 3 070-4 900 mg/L and othertypical operation parameters. As a result of our investigation, we have found that the typical operation parameters tend to change within the range between 3 070 -4 900 mg/L with the volume loads being 2.76 kg COD/(m3.d),3.15 kg COD/( m3.d), 3.68 kg COD/( m3.d), 4.42 kg COD/(m3.d) and 5.52 kg COD/(m3.d) respectively. At the same time,the pH change takes place in the order of 6.5,7.0,7.5, 8.0,8.5 and 9.0, respectively, with the temperature changingwithin the range of 20℃,25℃,30℃,35℃and 40℃respectively, and the reflux ratio changes within the range of 0, 20%, 40%, 60% and 80%. Furthermore, we have investigated in this paperthe size of granular sludge during the stable operation period and optimized the operating parameters and the microscope photographs. The results of our study indicate that it is possible to remove the COD in pigsty sewage effectively by the UASB technique. Furthermore, we have a-l so found that there exists some kind of objective relation between the treating effects and the influential factors, such as volume load, pH value, temperature, reflux ratio, and so on. The study results of ours showthatthe removal efficiency of the COD in the sewage tends to increase firstly and then drop. In a more detailedway, the removal rate of COD turns to be about 85% when the volume load, pH value, temperature and reflux rate are 3.68 kgCOD/(m3.d), 7.0, 35℃ and 40%, respectively. The mass of anaerobic sludge, whose size would be 1.0-2.0 mm on an account of 69.56% of the whole mass of sludge. The results of microscopic examination suggest that there exist lots of coccus and bacillus on the surface of anaerobic granular sludge, which helps us to inferthat the abundant bacterial community might have been playing an important role in keeping the predominant treatment efficiency of the UASB technique.