Experimental Study on Gas-liquid Two Phase Flow Measurement Using Coriolis Flowmeter

ZHU Xiao-qian,WANG Wei-wei,DAI Yong-shou
DOI: https://doi.org/10.3969/j.issn.1002-1841.2011.03.009
2011-01-01
Abstract:Two parametric measurement of gas-liquid two-phase flow based on Coriolis mass flowmeter was studied.In the experiment,liquid flow was maintained at a fixed value,experimental data were collected under different gas void fraction.According to Weisman vertical upward gas-liquid flow pattern maps,the flow pattern of gas-liquid two-phase flow in the tube was analyzed.Combining with experimental results,the relationship among gas volume fraction,flow pattern and Coriolis flowmeter measurement accuracy was summed up,the main influence factor on the Coriolis flowmeter measurement accuracy due to the presence of aeration and its influence rules were summarized,which provided a new method for further study on gas-liquid two-phase flow measurement error correction using Coriolis flowmeter.
What problem does this paper attempt to address?