Thermal Runaway Risk and Vent Sizing of Dicumyl Peroxide

DENG Ji-ping,SUN Xin,CHEN Wang-hua
2013-01-01
Abstract:In order to investigate the thermal runaway risk of DCP and design the relief system size,a Phi-TEC II calorimeter was used to test thermal decomposition behavior of 30% DCP,data on temperature rising rate and pressure rising rate as functions of temperature were obtained. The results indicated that under adiabatic conditions the exothermic onset temperature was 145 ℃,the corrective heat of reaction was150. 5 kJ / kg. According to the relationship between temperature and pressure in heating and cooling process,the emergency relief system for DCP solution was identified as a hybrid system. Based on Leung methods,the relief sizes of a certain DCP solution tank were calculated as a tempered hybrid system and non-tempered hybrid system,the required relief areas were 0. 001 2 m2and 0. 003 7 m2respectively.
What problem does this paper attempt to address?