Thermal safety assessment for solid organic peroxides

Shang-Hao Liu,Yan-Ru Wang,Cheng-Lei Xiong,Mitali Das
DOI: https://doi.org/10.1016/j.jlp.2020.104292
IF: 3.916
2020-11-01
Journal of Loss Prevention in the Process Industries
Abstract:<p>The thermal hazards of dicumyl peroxide (DCP) and benzoyl peroxide (BPO), self-reactive chemicals are identified and characterized using high-pressuredifferential scanning calorimeter, and simultaneous thermogravimetric analyzer, a C80 micro-calorimeter is used. The apparent exothermic onset temperature of DCP is found to be between the range of 112–122 °C for different heating rates in DSC tests. There are two coupled peaks of BPO around 105 °C at both the heating rates of 4.0 and 8.0 °C/min while no endothermic peak showed at lower heating rates. Furthermore, another endothermic peak appears immediately after the exothermic peak at about 211 °C of DCP under high-pressure conditions. For BPO, the endothermic peak before the exothermic peak disappears as the pressure increases to 1.0 and 1.5 MPa. The average values of apparent activation energy calculated by Flynn-Wall-Ozawa and Kissinger-Akahira-Sunose methods during the conversion rate between 15 and 75% of DCP are 80.69 and 74.05 kJ/mol, and that of BPO are 119.96 and 112.93 kJ/mol, respectively. According to the isothermal tests, the thermal decomposition of DCP behaviors is an <em>n</em>-th order reaction while BPO conforms to the laws of autocatalytic reaction.</p>
engineering, chemical
What problem does this paper attempt to address?