Analysis of the thermal hazards likely to be caused by the synthesis of benzoyl peroxide

Jun JIANG,Jia-jia JIANG,Jun-cheng JIANG,Wen-xing ZHANG,Yuan YU,Fa-ming CHEN
DOI: https://doi.org/10.13637/j.issn.1009-6094.2017.02.009
2017-01-01
Abstract:In this paper,we would like to introduce our analysis results on the thermal haphazards likely to be caused with in the synthesis of benzoyl peroxide via the RC1e (Reaction Calorimeter).Benzoyl peroxide (BPO),historically speaking,has been known as a risk-prone chemical polymer that may lead to lots of serious fire and explosion accidents due to its broad use in the world.In order to prevent and reduce such accidents,the present author is inclined to propose the following aspects to make thorough research to work out more effective and long-range efficient way out to avoid such hateful and disastreous technical hardnuts.Therefore,we would like to recommend the following approaches at least as prewamings in this aspect.First of all,we do think it is of great significance to study the exothermic processes under different NaOH solutions to obtain the thermal hazard coefficients,which should be controlled at about the solution concentrations of 1.96 mol/L,3.93 mol/L,7.14 mol/L,respectively.And,secondly,more efforts should be oriented to the study of the thermal decomposition process of the aforementioned product by PHI-TEC Ⅱ to analyze its thermal stability.And,last of all,it is also necessary to evaluate the likeliness of the runaway reactions and the thermal risks of the synthetic process itself.In so doing,we would eventually bring forward the following suggestons:when the concentration reaches 7.14 mol/L,there will be great risk probability for the heat generation rate,that means,it would be the ending of the early stage in safety and beginning of the highest in the later stage for the risk.The adiabatic temperature rise (△Tad)and the maximum temperature of the synthesis reaction (MTSR) would like to reach the highest concentration.At this stage,the adiabatic temperature rise tends to prove to be 97.49 ℃,which should be attributed to the medium risk level.At this moment,the heat conversion would be fastest when the concentration comes to be 3.93 mol/L.And,then,it would be possible to make all the exothermic onset temperature,the activation energy,and the pre-exponential factor of the BPO product of RC1 e lower than the pure BPO,because it is very easy to decompose the BPO product of RC1e.Thus,as a result,we have worked out that the temperature for its decomposition should be at 49.81 ℃,when the time needed for the maximum reaction rate under the adiabatic condition of benzoyl peroxide is 24 h (TD24).Therefore,the evaluation results of the synthetic process demonstrate that the risks may remain too high to be accepted,which means that what we have concluded in this paper can not only help to improve the safety of BPO reaction and storage,but also provide technical supports for the originally settled stability criteria of the BPO decomposition reaction.
What problem does this paper attempt to address?