Analysis on Optimization Control of BAF Backwash

Li-long YAN,Xing-jian WANG,Wei-guang LI,Yuan REN,Ying ZHANG
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2011.11.027
2011-01-01
Abstract:In order to optimize the backwash parameters of biological aerated filter(BAF),from the point of decreasing energy consumption,and using model analysis and mathematic derivation,an optimal period formula of BAF backwash was built,and the optimal backwash parameters were determined.The effect of backwash parameters on microorganisms was investigated.The results show that the optimal backwash period is the corresponding operation time of filter when instantaneous water producing rate equals to periodic average water producing rate,and the water producing rate is maximum at this time.The optimal parameters are calculated by the formula as follows: air wash for 3 min,air-water wash for 5 min and water wash for 10 min with water intensity of 9 L/(m2·s) and air intensity of 18 L/(m2·s).The backwash parameters influence microorganisms greatly,and the loss rate of biomass is maximum at the inlet of BAF.The optimal backwash periodic formula can not only improve efficiency of filter and save energy consumption,but also be used to help achieve automatic control of backwash.
What problem does this paper attempt to address?