Determination of Neomycin in Neomycin Sulfate Eye Drops by Rapid Colorimetric Assay

何梅凤,吴伟,王延东,唐细兰
DOI: https://doi.org/10.3969/j.issn.1672-2809.2006.03.014
2006-01-01
Abstract:Objective To develop a rapid method for the determination of neomycin eye drops.Methods Colorimetric method was used for the determination of neomycin sulfate eye drops at wavelength 594nm,based on the fact that neomycin and Cu2+ can form blue complex in alkalescent condition and exhibit a stable characteristic absorption.Results At the range of 1000u~6000u/ml,absorption and concentration of neomycin had good linear correlation,the correlation coefficient(r) =0.9998,the average recovery rate was 100.67%,RSD was 0.74%.Conclusion This method is convenient,rapid,accurate and good recurrence,thus it can be applied to quality control of semi-finished product and the rapid analysis of preparation in hospital.
What problem does this paper attempt to address?