A forced dust collection technology for high-dust-concentration air flow in ESP electric field

HAO Wenge,PEI Yingying,CHEN Peng,XU Xinyang
DOI: https://doi.org/10.3969/j.issn.1008-0562.2009.03.045
2009-01-01
Abstract:Dust concentration is normally very high around the dust arresting plate of electrostatic precipitation. An air catcher can be installed at the end of ESP in order to suck in dusty air at a constant velocity and purify air efficiently. The method can increase the efficiency in dust collection. In order to accurately describe the characteristics of sectional concentration distribution at the exit of electrostatic precipitation, and obtain the relationship between air quantities sucked in and dust collection efficiency, the finite difference method (FDM) is used to solve the two-dimensional particle transport equations of electric field particles. Comparing the equation results with the experimental results, both results are very close. It proves that the transport equation is valid and the computing method is practical. According to the simulation on sectional concentration distribution at the exit and the characteristics of constant velocity air catcher at the end of electrostatic precipitation, a relationship between the height of air catcher and the efficiency of dust removal can be obtained. The relationship can be used to calculate the compulsory air quantity for meeting discharge limits.
What problem does this paper attempt to address?