Experiments and Numerical Simulations of the Removal of Fine Particles in the Coupling Field of Electrostatic Precipitators

ZHOU Dongliang,LI Shuiqing,JIN Xing,XIONG Guilong,HUANG Wei
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2016.02.016
2016-01-01
Abstract:The capture of fine particles in the coupling of electric field and flow field is not only an essential problem for the power plant dust removal system, but also a key issue for power components and optical components in the aerospace environment. Through experiments and numerical simulations of electrostatic precipitators (ESP), the transport and capture characteristics of fine particles in the coupling electric field and flow field were investigated. The results show that there is a penetration window in the 0.1-1μm size range. The change of dust concentrations is not proportional to the residence time, and there is a high-efficiency region where the residence time is about 1.5-2 s. After that, the influence of residence time is not obvious for particles in the 0.1-3μm range. The potential distribution, electric field intensity and collection efficiencies were obtained by numerical simulations. With the Cunningham slip correction of drag forces, the simulated collection efficiencies are consistent with the experiment results for particles smaller than 1μm. The Cunningham slip correction is important for the simulation of collection efficiencies for sub-micrometer particles.
What problem does this paper attempt to address?