Enhanced Flocculation As the Pretreatment for Biopollutant Laboratory Wastewater
YANG Nan-zhen,LIU Yan,ZHANG Yun,GUO Si,CAI Xuan,SHI Zhou,LIU Xiang,AN Dong
DOI: https://doi.org/10.15943/j.cnki.fdxb-jns.2009.01.011
2009-01-01
Abstract:The biopollutant laboratory wastewater produced with the development of biological technology has potential threaten for both human health and environment.The effects of several major factors,the coagulants PAC,PFS,PAFCS,the ratio of CaO over LAS(in mole),coagulant aid PAM,temperature and pH,respectively were investigated by single factor experiment.The results show that PAFCS is the best coagulants.To remove a kg COD,the amount of PAFCS needed was one-sixth of PAC or PFS,and the cost of the coagulant was one-fifth.The optimal values were PAFCS 40mg·L-1,CaO/LAS 0.75,PAM 1mg·L-1,temperature 25℃,pH 7.Under the optimal condition,the removal efficiencies of COD,LAS,bacterium,and ATP were 58%,53%,94%,and 92%,respectively.