Validity of A Novel Portable Physical Activity Monitor with a 3D-Accelerometer and a Barometer: 2863

Ryoichi Nagatomi,Xiumin Zhang,Hidetaka Yamaguchi,Mitsuharu Okutsu,Kenji Ishii,Akihiro Suzuki,Yasuaki Ohtaki,Koichi Sagawa,Hikaru Inooka
DOI: https://doi.org/10.1249/00005768-200605001-03198
2006-01-01
Abstract:BACKGROUND: Quantitative assessment of physical activity is important in epidemiological and clinical research related to lifestyle-related diseases such as obesity, diabetes, coronary heart disease, hypertension, and hyperlipidemia. We developed a novel portable device with a 3D accelerometer and a barometer, Intelligent Calorie Counter (ICC). PURPOSE: To examine the reliability and the validity of ICC in the classification of physical activities and in the estimation of energy expenditure during a variety of physical activities. METHODS: ICC classifies physical activities into following categories according to 3D acceleration and differential atmospheric pressure data; 1) level walking, 2) running, 3) climbing up/down stairs or hill, 4) going up/down in or on a vehicle, 5) sedentary and 6) miscellaneous activities not categorized to the first 5 categories. Energy expenditure was calculated according to the formula for each category of physical activity. The formula of activity category 1)-3) for energy expenditure was generated according to the regression of step rate and oxygen uptake of each category of activity measured independently. Eight healthy male subjects [age: 24.9 ± 0.69 (mean ± SE) yr] volunteered for the study. This study was approved by the Ethical Committee of Tohoku University School of Medicine, and all the subjects gave their informed consent. Energy expenditure was measured by both ICC and AT-1100, a portable expiratory gas analyzer (AT1100, Anima Co., Tokyo, Japan) together. ICC was attached firmly to the waist and AT-1100 was carried on the back of the subject. In experiment 1, the subjects performed a series of activities (standing, level walking, going down in elevator, going up in elevator, stair climbing down, and stair climbing up). In experiment 2, the subjects performed an assigned activity (level walking, or stair climbing up or down). RESULTS: ICC classified physical activity patterns including static, level walking, down/up on a vehicle or a lift, stair down/up successfully. Energy expenditure estimated by ICC showed a high correlation with the energy expenditure calculated from the measured oxygen uptake by AT-1100 (r=0.971, p<0.0001). CONCLUSION: ICC is the first successful portable device to assess and quantify daily physical activity 3 demensionally. It provides a simple and accurate method for classification of activities and estimation of energy expenditure of daily physical activity. This research is grant aided by Japanese Ministry of Education, Culture, Sports, Science and Technology; Intelligent Cluster Project.
What problem does this paper attempt to address?