Validity and Reliability of Perception Digital Pedometers in Measuring Step Count, Distance, Energy Expenditure and Heart Rate during Exercise

Stanley Sai-chuen Hui,Lin Wang,Xu Wen,Kiwi Wing-yee Chan
DOI: https://doi.org/10.1249/01.MSS.0000402026.32643.c0
2011-01-01
Abstract:PURPOSE: The purpose of this study was to determine the validity and reliability of Perception Digital (PD) pedometers in measuring step count, distance, energy expenditure and heart rate (HR) during exercise. METHODS: A total of 36 male participants aged 19 to 53 years volunteered to participate in this study. Six PD pedometers were worn on different locations of the body. Four on the waist including the anterior mid-line of the right thigh and posterior mid-line of the right thigh, anterior mid-line of the left thigh and posterior mid-line of the left thigh. In addition to the four waist-mounted sites, a PD pedometer was worn on a belt at the right mid-arm (anterior biceps) and another PD pedometer was hanging inferior to the chin near sternum head of mid-chest by a short string around the participant's neck. Three other models (Omron, Yamax and Oregon Scientific) were also mounted on the waist according to the manufacturer's instruction for data comparison. A COSMED K4b2 portable metabolic analyzing system was mounted on the participant for measuring real-time energy expenditure and HR. The participant then took part in a 1600m walking and a 1600m jogging around a 400-meter outdoor track respectively. Total steps, distance, energy expenditure as well as HR during both walking and jogging were recorded. RESULTS: The reliability of all measures (step counts, distance travelled, energy expenditure and HR) of walking and jogging were very high (α>0.90) while HR measures of jogging was good (α=0.796). The highest reliabilities were found between the PD pedometers at anterior waist sites. The validity coefficients of step count and HR measure were high in both walking (step count: r= 0.885 to 0.986; HR measure: r= 0.901 to 0.902) and jogging (step count: r= 0.789 to r=0.995; HR measure: r= 0.881 to r=0.935). Step count errors of PD pedometers for both walking and jogging were less than 0.5%. For distance traveled, the PD pedometers over-estimated about 2.4% to 3.4% errors for walking and 3.7% to 7.5% errors for jogging. For energy expenditure, the validity coefficients for PD pedometer were low to moderate, ranging from r=0.203 to r=0.491. CONCLUSION: Overall, the reliability and validity of most movement and HR measures from PD pedometers were satisfactory.
What problem does this paper attempt to address?