Colorimetric Evaluation of the Shade Match of Solidex Resin Specimens and Vita Shade Tab

邢文忠,蒋滔,王贻宁,陈小冬
DOI: https://doi.org/10.13701/j.cnki.kqyxyj.2010.04.027
2010-01-01
Abstract:Objective:To evaluate the shade match of Solidex resin specimens and Vita shade tab.Methods:The study tested three shades(A1,A3,and C2)Solidex body materials in accordance with the Vita shade guide.Resin specimens were fabricated to 2.0mm thick and 10.0mm diameter.Composite resin Z100(4.0mm thick and 10.0mm diameter),A1,A3,C2shade,were as background.The CIE L*a*b*values of specimens and shade tab were measured by a colorimeter(ShadeEye NCC)to calculate the colorimetric.After colorimetric evaluations were made,the reduction and polishing process was repeated with silicon-carbide paper to achieve final thickness of Solidex resin specimens to 1.8,1.6,1.4,1.2and 1.0mm.Color differences(ΔE)were calculated between Solidex resin specimen and shade tab.Results:The color difference of resin specimens and shade tab was from 6.18to14.29.The color difference increased following the decrease of resin specimen thickness.Conclusion:Color differences in this study are unacceptable in clinical condition.