Abstract:Natural draft cooling tower is an important part of the coal-fired power plants,usually include the rotating shell,herringbone column,the ring beam,the basis and so on.In the large-scale power plant cooling towers in general are 140m,which are studyed widely at home and abroad,need to be done using special wind tunnel tests and the design process,such as LBSD,RBSA,and so on.While in the small-scale coal-fired power plants hyperbolic cooling tower is 60m and there is very little information related to this part.In this paper,the commercial finite element program ANSYS is used to calculate the deformation,stress and linear stability un-der the gravity and wind load.The results of this article can supply an important reference for the similar pro-ject.