Research on Online Fouling Removal of Spiral-Flow Fluidization in Falling Film Evaporator

魏彪,俞天兰,彭德其,张梅
DOI: https://doi.org/10.3969/j.issn.1671-8909.2011.12.002
2011-01-01
Abstract:To solve the fouling problem of falling film evaporator,a new online fouling removal technology of spiral-flow fluidization is developed.According to the equivalence principle of crystallization rate,the crystallization of supersaturated solution on heating tubes in evaporators is equivalent to that on cooling tubes of heat exchanger in experiments.Saturated sodium sulfate solution flows through the cooling tubes at the average speed of 0.4 m/s.The results show that as the absolute supersaturation near the tube surface(Δcsur) is 4.20%,the total heat transfer coefficient is not reduced under the condition of tubes with steel spiral-insert after continuous operation of 0.5h while it decreases by 80% under the condition of hollow tubes.When Δcsur is more than 5.60%,the total heat transfer coefficient will decrease.However,the total heat transfer coefficient does increase by 6% not decrease under the conditions of spiral-insert and fluidization of 1% volume fraction of particles,when Δcsur is 6.46%.The technology of spiral-flow fluidization can not only remove fouling online and automaticly,but also enhance the convection heat transfer in tube side.With its simple structure,it can be applied in process industry.
What problem does this paper attempt to address?