Instrument Design, Measurement and Analysis of Cardiovascular Dynamics Based on LabVIEW
Wei He,Hanguang Xiao,Songnong Li,Delmo Correi
DOI: https://doi.org/10.5772/22674
2011-01-01
Abstract:With the increasing aging of population, cardiovascular diseases have become one of the most common diseases. It has been recognized as the leading killer of the 21st century by World Health Organization (He & Yu 2010). It is believed that one-third of deaths around the world result from cardiovascular disease, but many of them died from absence of timely detection of the diseases (Mark 2003). Therefore, timely and accurate detection and diagnosis of this kind of diseases are of great significance for prophylaxis and treatment. For this purpose, more powerful instruments are needed to be developed. In recent years, LabVIEW have been wildly used in various fields as a powerful development environment and platform based on graphical and dataflow programming language (Johnson & Jennings 1997; Whitley & Blackwell 2001; Klinger 2003; Bitter et al. 2007). LabVIEW-based research and development of medical instruments is one of the most outstanding representatives in the R&D of virtual instruments (He & Yu 2010). In this chapter, we will introduce the design of our independently developed product, which is named as YF/XGYD atherosclerosis detection system developed by LabVIEW. Three aspects of the system will be mainly described, namely overall design of the hardware system, the brief design and LabVIEW realization of the software system, and the clinical measurement and analysis of hemodynamic parameters of cardiovascular system, such as pulse wave velocity (PWV) and arterial stiffness index (ASI). In the first part of the chapter, we will mainly described the overall design of the hardware system, such as the measure method of analog signals of blood pressure, the design and realization of the signal processing circuit, the design of digit circuit and loop of aeration and deflation, and the circuit of motor control. In the second part of the chapter, the overall framework of the software system will be displayed in a block diagram. Then, the interface design of the software system is described, for example the main interface, test interface and record interface. In addition, we will show how to build and manage the patient database of the software system. Finally, the basic principle, measurement and analysis of two key parameters are introduced, namely PWV and ASI. We would like to apply the system to clinical test and discuss the performances of the system.