High frequency standing-wave thermoacoustic engine with sinusoidal resonance tube

Yu Bo,Dai Wei,Luo Ercang,Yu Guoyao,Zhang Xiaodong
DOI: https://doi.org/10.3969/j.issn.1000-6516.2009.01.001
IF: 2.134
2009-01-01
Cryogenics
Abstract:A symmetrical pipe whose cross-sectional area changes sinusoidally was designed as the syntonic pipe of the high frequency standingl-wave thermoacoustic engine.The performance and output characteristics of the engine with such resonance tube were investigated experimentally and compared with the engine with constant-diameter resonance tube.The experiment result showed that sinusoidal tube can effectively inhibit second order harmonic mode,increase first order pressure amplitude and lower down heating block temperature.Due to obvious nonlinear effect,the calculation based on linear thermoacoustic theory cannot forecast the difference between these two kinds of resonance tubes and has a large deviation from the experiment results.
What problem does this paper attempt to address?