Intensity-Modulated Radiation Therapy for Whole Pelvic Irradiation in Cervical Carcinoma Patients after Hysterectomy-Phase I–II Study of FUCH

Y. Lin,L. Zhou,S. Cai,Z. Xu,X. Guo,Z. Zhang,X. Fu,G. Jiang
DOI: https://doi.org/10.1016/j.ijrobp.2009.07.872
2009-01-01
Abstract:To establish the technique of intensity-modulated radiation therapy (IMRT) for whole pelvic irradiation in cervical carcinoma patients after hysterectomy in Fudan University Cancer Hospital (FUCH). In addition, to observe the treatment results and side effects of the treatment. All patients enrolled in this study should be cervical carcinoma after hysterectomy with high-risk of pelvic recurrence. The prior-clinical study was done in 10 patients to establish the technique of IMRT. (1) Patients were immobilized by vacuum-lock or belly-board with prone positions and set-up errors were measured three times a week at irradiation positions by comparison of DRR and EPID. Doses to bladder, intestine and colon were evaluated when bladder was full or empty. The set-up errors were also measured at prone position with full and empty bladder. (2) CTV was defined as regional pelvis lymph nodes and tumor bed, and was delineated by contouring pelvis vessels with 1 cm margin surrounding vessels. (3) Dosimetric parameter comparisons were carried out among irradiation plans. The goal was to deliver 45 Gy to CTV. After this study, the technique was established. One hundred patients were then enrolled and received IMRT. Concurrent chemotherapy was used weekly in 60 patients. The treatment outcome and side effects were recorded. (1) From 2004 to 2005, 10 patients enrolled for irradiation position study. The set-up errors were 3.0mm ± 0.7mm at anterior-posterior direction, 2.2mm ± 0.5mm at cranial-caudal direction and 1.5mm ± 0.2mm at left-right direction for prone position. Five patients were selected for study of bladder status. Comparisons of DVH of bladder, intestine and colon less doses to above organs were found with full bladder than empty bladder (p = .02, .04 and .03, respectively). With prone position and full bladder, the random error for set-up errors was 3.1 mm ± 1.2 mm, system error was 6.7 mm ± 1.1 mm, and total uncertainty was 7.4 mm ± 1.6 mm. For 95% confidence interval, the margin added from CTV to PTV could be 1 cm based on total uncertainty. (2) A guideline for delineation of CTV was proposed. (3) Dosimetric parameter compared and 110 irradiation plans had been generated for 10 patients. IMRT with 7or 9 field plan was recommended .Using this IMRT technique, 100 patients were treated from 2004–2008.The median following time was 3years.The overall survival was 95%. The DFS was 93%. The local control rate was 98%. The side effects were mild. The most common complain was diarrhea. Prone position with full bladder was the best irradiation position according to our guideline of contouring, and IMRT with 7or 9-field plan was appropriate. The treatment outcome was satisfied without severe side effects.
What problem does this paper attempt to address?