Hemocompatibility Evaluation of Poly(amido-Amine)polyelectrolyte Complexes.

TF XI,JC ZHANG,WH TIAN,XH LEI,Q SONG,P ZHENG
DOI: https://doi.org/10.1016/0267-6605(91)90008-4
1991-01-01
Clinical Materials
Abstract:A polyamido-amine from piperazine and methylene bisacrylamide was synthesized. Six polyelectrolyte complexes were obtained from the polyamidoamine and alginic acid, carboxymethyl cellulose or polymethacrylic acid according to different mole ratios. The hemocompatibility of these polyelectrolyte complexes was evaluated by testing of the kinetic blood clotting time and radioimmunoassay testing of the antibody SZ-21 (the membrane glycoprotein complex IIIa of human platelets). The polyelectrolyte complex of polyamido-amine and alginic acid with a 1:2 ratio was found to possess the best hemocompatibility.