Structure Optimization of Conical Spool and Flow Force Compensation in a Diverged Flow Cartridge Proportional Valve
Li Tan,Haibo Xie,Hanben Chen,Huayong Yang
DOI: https://doi.org/10.1016/j.flowmeasinst.2019.03.006
IF: 2.42
2019-01-01
Flow Measurement and Instrumentation
Abstract:In this article, a method aims at reducing the steady-state axial flow force working on the main spool of a diverged flow cartridge proportional valve was proposed. The maximum flow force of original main spool can reach as high as 24% of the control force, which will definitely cause a huge disturbance to the proportional control of main spool, and consequently, the work condition of valve will be in an unstable status. The main contents of this paper are as follows: first, describing the damping flange and its parameters which may influence the effect of compensation; second, the rule that how these parameters influence the flow force was found by a series of computational fluid dynamics (CFD) simulations, and then, according to the analysis, the optimal structure can be gained, besides, the effect of damping flange on pressure difference is also taken into account; at last, a test-bed was built up to validate simulative results. The experiment results shows that the result of simulation is reliable and the proposed methods is feasible.