Analysis on Gas Pulsation and Piping Vibration in the Piping System of Natural Gas Compressor

Xueyuan Peng
2008-01-01
Abstract:The analytical study on the gas pulsation and piping vibration in a natural gas pipeline was presented,based on which the measures are suggested to control the excessive vibration.With the gas pulsation model established,the natural frequency for the gas pulsation is obtained,the maximal pulsation amplitude together with the position is estimated,and the shaking forces inducing the vibration are calculated.In the vibration analysis,the vibration mode and the forced response of the piping system are predicted.Comparison associated with the pulsation and vibration between the original pipeline and the modified one shows that the maximum pressure pulsation in the modified pipeline decreases from 17.65% to 11.38%,the lowest natural frequency for structural vibration increases from 2.6Hz to 12.2Hz and the maximum vibration amplitude reduces from 0.393mm to 0.117mm.Validation test shows that the maximum vibration amplitude reduces from 0.4mm to 0.1mm at 380 r/min,which indicates that the pipeline modification on the basis of pulsation and vibration analysis is reasonable.
What problem does this paper attempt to address?