Quick Startup of Internal Circulation Anaerobic Reactor Using Low Intensity Ultrasound

CHEN Chen,MA Yong-wen,WAN Jin-quan,HUANG Ming-zhi
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2011.03.009
2011-01-01
Abstract:In order to find a way of quick startup of IC anaerobic reactor,using the granular sludge as the inoculum(SS=23.28 g/L),a comparison was made between one group using the granular sludge treated by ultrasound of 0.3 W/cm2 for 10 min and another group using raw granular sludge.The results show that after ultrasonic treatment,the startup time of IC anaerobic reactor can be shortened,just needs 7 days.The organic loading rate is 6 kgCOD/(m3·d),and COD removal rate is 95% at the end of startup.The low intensity ultrasound has little influence on morphology of granular sludge,without destructive action on microorganisms.On the contrary,the low intensity ultrasound can promote the growth and metabolism of microorganisms.The VSS/SS of treated sludge is 0.82 at the end of startup,more than that of raw granular sludge.The methanogenic activity is higher.The low intensity ultrasound can achieve quick startup of IC anaerobic reactor.