RP- HPLC Determination of Sodium Daidzein- 3' -Sulfonate

ZHOU Bao-shi,WANG Xiao-bing,ZHANG Yuan
2006-01-01
Abstract:Objective:The RP-HPLC assay was developed to establish method to determine the content of sodium daidzein-3′-sulfonate (SDS).Methods:The method was performed on a column of Hypersil ODS (250 mm×4.0 mm,5 μm),using MeOH-10 mmol.L~(-1)KH_2PO_4 (35:65)as the mobile phase at the detective wavelength of 254 nm with the flow rate of 0.8 mL·min~(-1).p-Hydroylbenzaldehyde was employed as the internal standard.Results:Sat- isfactory separation among SDS and related impurities was obtained.The calibration curve was linear overthe range of 1-40 μg·mL~(-1) for SDS(r=0.9999).The average recovery of SDS was 99.49%.Conclusion:The method is simple,sensitive and accurate and can be used for the quality control of SDS.The proposed method has been applied to the determination of SDS in medicine with satisfactory results.
What problem does this paper attempt to address?