Determination of Residue Tri(n-Butyl)phosphate in Medical Fibrin Glue Products

LIU Tingting,XU Chen,CHEN Yile,LI Yan,DUAN Gengli
DOI: https://doi.org/10.19577/j.cnki.issn10074406.2011.04.009
2011-01-01
Abstract:AIM To establish a capillary gas chromatography(GC) for the determination of residue tri(n-butyl) phosphate(TNBP) in medical fibrin glue products.METHODS Using tripropyl phosphate(TPP) as internal standard,a simple capillary GC method was developed with a DB - WAX capillary column(30 m×0.53 mm,1.0μm);the injection port temperature was 190℃;the detector temperature was 210℃;column temperature was 160℃;the carries gas was high purity nitrogen.RESULTS The linear range of TNBP was 1.61-12.84 mg·L~(-1)(r=0.999 4).At low,medium and high concentrations,the recovery of TNBP was 98.26%,99.26%and 95.98%respectively,and the RSD was 1.21%,1.19%and 0.43%(n=3)respectively.CONCLUSION The method is simple,precise and accurate,and can be used to determine residue of TNBP in medical fibrin glue products.
What problem does this paper attempt to address?