Correction Method of Flowrate Measured in Polymer Flooding Injection Well and Its Application

QI Li-wei,ZHANG Yu-hui,HUANG Chun-hui,JU Ming-yuan
DOI: https://doi.org/10.3969/j.issn.1004-1338.2007.04.020
2007-01-01
Abstract:Flowrate measured by memory-type electromagnetic flowmeter is different from practical flowrate in polymer flooding injection well.The cause believed is that the tool is used to be calibrated in lab with flow of fresh water,whereas it is practically used to measure solution of polymer,and unfortunately,the properties of the two media are obviously different. Calibration experiments in simulated wells show excellent linear relation between the flowrates and the outputs of the tool in both water or polymer,but the calibration factor in polymer is less than that in water,nevertheless,the calibration factors in different concentrations of polymer solution within the range of 500~2 000 mg/L are not obviously changed.The correction method of the flowrate measured in polymer flooding injection well with a tool calibrated in fresh water is presented.The field applications indicate that the method works rather well in wells with slightly scaled tube,however,it is limited in tubs with bad scale deposit and corrosion.