Problem Diagnosis and Analysis on Oxidation Ditch Process in a Wastewater Treatment Plant in Kunming

Xian-bao WANG,Peng-kang JIN,Xiao-chang WANG,Dang-cong PENG
DOI: https://doi.org/10.3969/j.issn.1000-4602.2012.13.003
2012-01-01
Abstract:According to the statistical analysis of monitoring data for oxidation ditch process in a wastewater treatment plant(WWTP) in Kunming,an on-site investigation was carried out.Problems during the operation of the wastewater treatment plant were diagnosed,and corresponding solutions were given.The low nitrogen removal efficiency was the major problem faced by the WWTP.The insufficient utilization of carbon source in raw wastewater,insufficient oxygen supply capability of aeration equipment,low concentration of dissolved oxygen in the bio-chemical treatment system,and high energy consumption were the main constraints to improving removal efficiency.The analysis suggested large room for optimization in the nitrogen removal process of oxidation ditch in the WWTP.Aiming at the process and the operation conditions of the WWTP,the step-feed microporous aeration variable speed oxidation ditch was proposed.
What problem does this paper attempt to address?