Application of simple interrupted suturing combined with hemodynamic plus valve in aortic valve replacement in small aortic annulus

Jianhua ZHOU,Yihua SUN,Haiquan CHEN,Xian ZHOU
DOI: https://doi.org/10.3969/j.issn.0253-9934.2007.09.011
2007-01-01
Abstract:Objective To evaluate the outcome of simple interrupted suture technique combined with hemodynamic plus(HP)valve for aortic valve replacement in the small aortic annulus.Methods Seventeen patients with small aortic annulus received aortic valve replacement using HP valve combined with simple interrupted suture technique.The aortic annulus diameters were 19-22mm as determined during operation.Doppler echocardiography was preformed in all patients one week after operation.Results There was no death or serious complication in our group.After operation, significant increases were observed after operation in the left ventricular dimension end diastole([61.5±10.3]mm vs[49.1±9.4]mm,P<0.01),left ventricular mass index([126.5±35.1]g/m~2 vs[80.6±18.6]g/m~2,P<0.01)and peak pressure gradients across aortic valve([82.6±52.6]mmHg vs[21.6±12.6]mmHg,P<0.01, 1 mmHg=0.133 kPa).The patients' heart function was significantly improved after operation according to NYHA cardiac function classing(x~2=42.610,P<0.01).Conclusion Simple interrupted suture technique combined with HP valve is a safe,effective method for aortic valve replacement in small aortic annulus.(Shanghai Med J,2007,30:683-685)