A vitro study of marginal adaptation of different fabrication methods on copings

SHAO Jin-long,WANG Bing,DING Wei-shan,LI Ying
DOI: https://doi.org/10.3969/j.issn.1009-3761.2013.03.007
2013-01-01
Abstract:Objective: To compare the marginal adaptation of casting restorations whose wax pattern fabricated by traditional method and CAD/CAM respectively and resin pattern fabricated by CAD/CAM.Methods: Eighteen type IV stone dies were pored with a silicone impression,and divided into A,B,C groups randomly.Six wax patterns for full-coverage coping crowns were fabricated by a traditional method in A group,while six wax patterns and six resin patterns were fabricated by a CAD/CAM system in B and C groups,respectively.All the patterns were invested and casted to fabricate crowns.The crowns were seated on the dies according their symbol sites.Their vertical marginal gap was taken pictures by Leica microscope,measured using Image-Pro Plus 6.0,and analysis by ANOVA and t test using SAS9.13.Results: The vertical marginal gap in A group was 68.20±24.30μm,in B group was 46.31±23.43μm and in C group was 60.58±21.87μm.All results were below 120μm.Significant differences were found among three groups(P = 0.0061).There was no significant difference between A group and C group(P = 0.2600),and significant differences were found both between A group and B group(P = 0.0027) and between B group and C group(P = 0.0343).Conclusion: Wax patterns fabricated by CAD/CAM had better marginal adaptation.High quality crown casting was obtained using a combination of wax patterns fabricated by a CAD/CAM system and a traditional casting method.
What problem does this paper attempt to address?