Determination of deoxynivalenol in grains and beans by capillary gas chromatography

Ma Yi-yi,Guo Hong-wei
DOI: https://doi.org/10.3969/j.issn.1004-8685.2007.05.010
2007-01-01
Abstract:Objective:To set up a GC method to determine deoxynivalenol in grains and beans.To explore the advantages and disadvantages of this method compared with ELISA.Methods:Deoxynivalenol was extracted with methanol/water(3:1) and purified by a chromatographic procedure using florisil columns.By means of the DB-5MS capillary gas chromatographic columns and mini electron capture detector,the amount of deoxynivalenol could be determined with good precision and accuracy.Results:The limits of detection was 1.78 μg/kg.Recoveries of toxins added to negative samples at 0.09,0.15,0.3 μg/ml were 86.84%~101.85%.The relative standard deviation of the method was lower than 10%.Conclusion:This method has great sensitivity,precision and accuracy.By comparing with ELISA,capillary gas chromatography is better.
What problem does this paper attempt to address?