Study on effectiveness of smoke exhaust in large flat space using hot smoke experiment

WU Wei-jun,XU Liang,TAO Li-hua,CHEN Xun,YAO Jia-jie
DOI: https://doi.org/10.3969/j.issn.1009-0029.2012.10.006
2012-01-01
Fire Science and Technology
Abstract:The effectiveness of mechanical smoke exhaust system in typical flat large space by using full size hot smoke experiment was studied.Different smoke partition area,smoke exhaust quantity,smoke vent position and smoke vent quantity have been used in the research to study the effectiveness under different working conditions.This paper has found that smoke distance on smoke effects is relatively large : if the distance is beyond a certain standard,smoke can not be well controlled.When there are two or more smoke well-distributed vent in the smoke partition,smoke effect is obviously superior to that with a single smoke vent.At the same time,smoke exhaust quantity calculated by the theory formula can effectively control smoke spread.Also smoke exhaust volume calculation method in Chinese codes are7relatively conservative.Flue gas dispersion and flue gas backfill phenomenon is also discussed and analyzed.
What problem does this paper attempt to address?