Simultaneous Determination of Carbaryl and Atrazine in Water by HPLC

FENG Yuan,YANG Li-li,ZHOU Jing-bo,YANG Zhi-jie
DOI: https://doi.org/10.3969/j.issn.1006-2009.2013.05.011
2013-01-01
Abstract:Carbaryl and atrazine in water were extracted by dichloromethane,and then the samples were enriched by rotary evaporator and nitrogen blowing instrument. The extracts were determined by HPLC and detected by a diode array detector at 222 nm. The results indicated that the good linear ranges for carbaryl and atrazine were 0. 100 mg / L to 5. 00 mg / L and the detection limits were 0. 031 μg / L and 0. 027 μg / L respectively. For blank samples,the standard addition recovery was repeatly determinated for 3 times,and the recoveries of the two target compounds were from 78. 5% to 91. 7%,and RSD were less than 5%.
What problem does this paper attempt to address?