Feasibility of Fast Kvp Switching Dual Energy CT in Molecular Imaging:A Preliminary Study

容蓉,丁杰,王霄英,姜原,蔡文超,邱建星,宋玉军
DOI: https://doi.org/10.3969/j.issn.1000-0313.2012.07.003
2012-01-01
Abstract:Objective:Using dual energy CT to measure the contents of iron and silver in Fe3O4 and single silver nanoparticle solutions with different concentration and to investigate the feasibility of quantitative analysis of Fe3O4 and single silver nanoparticles by dual energy CT.The results were correlated with MRI findings.Methods:Eleven Fe3O4 nanoparticle solutions and thirteen silver nanoparticle solutions in different concentration were prepared and examined by using MRI T2*GRE sequence.Their relative signal intensities were measured.Pearson correlative analysis was calculated to find out the relative signal intensities with that of theoretical real concentration.If significant correlation was existed,further linear regression analysis would be made.Dual energy CT(Discovery CT750 HD) with gemstone spectral imaging(GSI) mode was also used to examine the above mentioned solutions.GSI based on iron/water and iodine/ water as control,3 levels were chosen to measure iron and silver in these solutions.The effective Z-number and CT values of the mixed energy maps were measured.Pearson correlation analysis and linear regression of these CT value and real theoretical concentration were calculated as well.Results:Relative signal intensity of Fe3O4 nanoparticles in T2*GRE images had correlation with its real concentration(r=-0.940,P0.01),and the linear regression was good(R2=0.8836).Relative signal intensity of single silver nanoparticles in T2*GRE images had no correlation with its real concentration(r=-0.226,P=0.457).The measured concentration of Fe3O4 nanoparticles solution by dual energy CT had correlation with that of real concentration(r=0.682,P0.05),with moderate linear regression relation(R2=0.4697).Effective Z-number of Fe3O4 nanoparticles had no significant correlation with its real concentration(r=0.193,P=0.57),the CT values had no correlation with its real concentration as well(r=-0.149,P=0.662).Measured concentration of single silver nanoparticles had correlation with its real concentration(r=-0.926,P0.01),and the linear regression was good(R2=0.8482),the measured effective Z-number showed significant correlation with real concentration(r=0.934,P0.01) with good linear relation(R2=0.8643) as well,no significant relationship between CT value and real theoretical concentration(r=0.064,P=0.835).Conclusion:Using MRI to analyze the concentration of Fe3O4 nanoparticles is superior to CT GSI quantification,while for single silver nanoparticle,spectral CT might have potential for application.
What problem does this paper attempt to address?