Experimental study on CFRP-strengthened reinforced concrete plate girder bridge

Li Guibing,Guo Yugang,Wang Laili
2010-01-01
Abstract:The left lane of San-li Bridge is composed of eight plate girders.To evaluate its healthy state,an in-site static test was carried out on the left lane.The test results show that these girders cannot satisfy the provisions of the national code.Based on the test results,externally bonded CFRP laminates on the soffit were used to strengthen these girders.The test results of the strengthened girders show that the stiffness of the plate girder improved significantly.As a result,its safety stock under the applied load level of Qi-20 can meet the transportation requirements of the development plans in the near future and the strengthened girders satisfy the requirement of the code.The cost of using CFRP strengthening is 54% saved than that of using prestressed reinforced concrete beams.
What problem does this paper attempt to address?