Performance and Charge Analysis of Propane and Propylene Used in Low Temperature Cabinet Freezers

钱文波,晏刚,冯永斌,李景艳
DOI: https://doi.org/10.3321/j.issn:0253-987x.2009.09.023
2009-01-01
Abstract:The study was performed on the replacement of the refrigerants such as R22 and R404A with hydrocarbons(HCs) in low temperature cabinet freezers.The refrigerant cycle performances of HCs and R22,etc.under low-temperature conditions were compared via our computing program.According to the charge requirement of HCs in the EU standard EN378,a theoretical charge model was established and the charge was calculated for R1270(propylene),R290(propane) and R22 in a cabinet freezer,respectively.The results show that the pressure ratio and discharge temperature of R1270 or R290 are lower than those of R22,and the coefficient of performance is higher than that of R502,R507A or R404A.Moreover,the comprehensive performance of R1270 or R290 is better than that of R22,R502,R507A or R404A.In addition,the optimum charge of R1270 and R290 in a certain cabinet freezer is about 130 g and 110 g,respectively,far less than 220 g of R22.
What problem does this paper attempt to address?