Experimental Study of Flat Loop Heat Pipe With Bi-Transport Loops

莫冬传,邹冠生,潘亚宏,吕树申
2013-01-01
Journal of Engineering Thermophysics
Abstract:A flat loop heat pipe(FLHP) with bi-transport loops(BTL) is manufactured by using copper as shell and pure water as working fluid.The heat transfer characteristics of the FLHP with BTL are tested in different orientations.The results show that,the evaporator temperature can get to a steady state within a short time after the heat power changed,and the heat transfer capability of the two transport loops are almost the same.The evaporator temperature is very sensitivity to the orientation with smaller heating power,and it.is less sensitivity with larger heating power.When the heating power is the same,the orientation of along gravity(horizontal and the condenser is above the evaporator) gives the lowest temperature of the evaporator.This FLHP with BTL can transfer more than 360W in all orientation by limiting the evaporator temperature lower than 90°.Anyway,the condenser line was not full used yet,and it can transfer even larger heating power.