Study on Metal Hydride Canister

刘晓鹏,蒋利军,陈立新
2009-01-01
Abstract:The temperature field of the inner cylindrical canister was simulated by using finite difference method and 2D heat transfer model during the hydrogenation process.It is showed that a temperature gradient is distributed obviously in the metal hydride bed,and the centric place of the canister has the highest temperature.Therefore,heat assembled in the centric place must be intensively transferred to improve the hydrogen storage properties of the metal hydride canister.In order to improve the hydrogen absorption/desorption cycle performance of the canister,the cycle life of as-cast and melt-spinning TiV0.41Fe0.09Mn1.5 alloy was comparatively studied.It is indicated that the cycle life of the melt-spinning alloy is considerably longer than that of the as-cast one.The canister prepared by using melt-spinning TiV0.41Fe0.09Mn1.5 alloy has 94% of the hydrogen storage capacity after 3600 cycles.