Flow regime analysis and oxygen transfer measurement of multiphase flow in bubbling packed column

Zhang Shuo,Wang Dong,Zhang Xingwen,Yang Liping,Zhang Xinyang,Wu Wei
2012-01-01
Abstract:To study the multiphase flow regime and oxygen transfer in bubbling packed column,the effect of gas distributor style,sponge and ceramisite bio-medias on gas holdup εg、flow regime and gas-liquid mass transfer capacity was investigated.In the range of superficial gas velocity U,three apparent regimes were observed in the case of 81 holes(Φ1 mm) while no obvious transition regime in the case of 25 holes(less hole number) and 225 holes(less hole spacing).In churn-turbulent regime(U>0.118 m/s),there were no significant discrepancies in gas holdup among these three distributors.There was no obvious change in gas holdup as the sponge volume fraction εs<25%,whereas the gas holdup reduced and transition regime emerged ahead at 35% volume fraction.In heterogeneous regime,the volumetric mass transfer coefficient KLa enhanced significantly in the presence of sponge.The gas holdup reduced in the presence of ceramisite and there was no obvious difference in εg as a function of volume fraction.In the ceramisite system,KLa reduced as a function of εs.Compared with several aeration conditions,there were no significant differences in the oxygenation capacity per unit volume air,KLa/εg,which showed a minimal interval in the transition regime with 81 holes distributor indicating a lower oxygen transfer efficiency.Under specific operation conditions,KLa/εg was almost constant,which was an important reference on deep understanding of the oxygenation capacity in the system where two kinds of bubble populations coexisted.
What problem does this paper attempt to address?