Numerical simulation of the smoke spreading in the urban road tunnels with the grade dividing junctions
Jun-mei LI,Shan-shan LIU,Yan-feng LI,Jun CHANG,Yan LI,Chao CHEN
DOI: https://doi.org/10.13637/j.issn.1009-6094.2016.03.012
2016-01-01
Abstract:The paper is inclined to present a numerical simulation of the smoke propagation in the urban road tunnels with the grade dividing functions.As compared with the smoke spreading in the tunnels with a single entrance and exit,things tend to be more complicated with the smoke spreading in the underground road tunnels with the grade-dividing junctions,for there may exist more heat to be released,that is,the heating releasing rate (HRR) of the fire,the slope of the branch tunnels,the angle formulated between the main tunnel and the branch tunnels,the ratio of the cross-section between the main tunnel and the branch tunnels constitute all the likely factors that may impact the smoke releasing.Seeing the above said influential factors,we have made great efforts in exploring the problems of smoke mass flow distributions between the downstream main tunnel and branch tunnels at the junction sections.The fire is supposed to be located at the upstream of the junction section,where there may exist four kinds of the fire-heat releasing rates,that is,those of 5 MW,10 MW,20 MW and 30 MW to be analyzed respectively,with four corresponding grades of the downstream branch tunnels,that is,those of 0,3%,6% and 9%.The results show that with the increase of the branch tunnel slopes,more smoke tends to be entering into the downstream tunnels,especially into the downward branch ones.Statistically speaking,almost about 75% of the smoke tends to enter and move towards the downstream tunnels whereas about 9% is motivating in the slope of the branch tunnels.However,about 60% of them is likely to pass through the branch tunnels.In such a situation,the temperature under the ceiling in the upstream main tunnel may turn to be decreasing,with little change of the temperature in the downstream tunnel being observed.With more smoke flowing into the downstream branch tunnels,the temperature in the branch tunnel goes to increase.At this,the smoke layers are likely to get blurred,which can be dangerous for the passengers or workers to move out from the tunnels.Thus,it can be concluded that HRR can be a great dangerous risk factor that impacts the smoke spreading along the tunnels,though it can make little impact on the smoke mass current distributions between the downstream main tunnel and the branch tunnels.