Study on Pressure-driven Liquid Flow in Microchannels Parallel Plate

LIU Kai-hui,XIAO Xiao-tian,LIU Ying
DOI: https://doi.org/10.13952/j.cnki.jofmdr.2010.05.027
2010-01-01
Abstract:Owing to the effect of the electric double layer in solid-liquid interface,the electrokinetic effect exists in the Pressure-driven flow of the microchannel parallel plate. The microchannel parallel plate can be simplified into a 2-D section,the governing equations of the double electrode layer and velocity field on the section are Poisson-Boltzmann equation and amended Navier-Stokes equation respectively. The numerical solutions of these equactions are obtained by the finite element method. And mean velocity in microchannel and streaming potential formed by electrokinetic effect are calculated. Research shows:microchannel height and electrolyte concentration are the main effect factors about the micro-fluid flow; the smaller the electrokinetic parameters,the greater effect of electrokinetic effects on the micro-fluid dynamic and the larger the actual values from the classical theory; also mean velocity and pressure differential at microchannel boths ends are linear correlation.
What problem does this paper attempt to address?