Research on Safety Pillar against Water in No.2137 West Lower Working Face, Zhaogezhuang Coalmine, Kailuan

Tan Jing,Zhang Putian,Hong Yiqing,Ma Yajie,Guo Liwen,Zhang Lige
2009-01-01
Abstract:The 2137 west lower working face in Zhaogezhuang coalmine,Kailuan is a deep buried,steeply inclined,extremely thick coal seam winning district.To prevent roof abandoned mine water bursting,design barrier pillar rationally,the FLAC3D simulating is used to analyze wall rock volumetric strain zoning characteristics under continuum large deformation condition.Combined with working face practical situation determined caving zone and fractured zone maximum heights,explained super-high repeated mining local caving phenomenon near the open-off cut in reason.Through computing,60m barrier pillar is designed that is less than15.75m of regulations stated.After two years of productive practice,demonstrated the design is on the safe side.
What problem does this paper attempt to address?