Heat Sinking Problem in Air-Cooled Semiconductive Air-Conditioning

XU Li-zhen,LI Yan,QIN Feng,CHEN Chang-he
DOI: https://doi.org/10.3969/j.issn.1673-5196.2008.01.014
2008-01-01
Abstract:Semiconductive air-conditioning system composed of two sets of semiconductive modules was designed.Input power of overall system was 170 W,refrigeratory space-600mm×600mm×600mm,and coefficient of performance COP-0.62.Experimental result showed that,20 min after the beginning of refrigeratory test,the temperature of refrigeratory space reduced by 11 ℃.Meanwhile,the influence of different coolant blocks on actual refrigeratory amount,and it was showed that there would be an appropriate thickness of refrigeratory block for the semiconductive thermoelectric pile.When such pile of TEC1-12708-type ran at 12 V and 2.8 A,with its thickness of 10 mm,a greater refrigeration capacity could be obtained.
What problem does this paper attempt to address?