STUDY ON HIGH-EFFICIENCY PHOSPHORUS REMOVAL OF A/O SYSTEM IN INTEGRATED RECLAMATION FOR MUNICIPAL SEWAGE AT LOW TEMPERATURE

Ma Jinming,Li Dong,Wu Di,Xu Da,Wang Bin,Zhang Jie
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2011.12.025
2011-01-01
Abstract:The stable operation of A/O biological phosphorus removal process under low temperature based on the concept of "Integrated reclamation flow for municipal sewage" was analyzed.The test showed that: Under low temperature conditions(10~14 ℃),the variation in influent loads had significant influence on effluent equality,moreover,with the NSCOD and dissolved oxygen(DO) at the level of 0.6 kg·kg-1·d-1 and 1~2 mg·L-1 respectively,a good effluent quality was obtained.The effluent concentration of TP was under 0.7 mg·L-1,the removal rate of TP reached 84%~96%.The effluent concentration of COD was under 60 mg·L-1,the removal rate of COD reached 80%~88%.There was enough alkalinity and VFA in influent to achieve better phosphorus removal efficiency without external adding.pH and ORP had significant relation on the phosphorus removal efficiency.The value of pH reflected the activity of PAO,It can achieve better efficiency at the high level of pH,the activity of PAO was at the high level;With activity of PAO increased,the ORP decreased.With minor nitrogen loss and little nitrite and nitrate accumulation,A/O system had little effect on nitrogen,which was important to offer stable influent for further nitrogen removal.