Stability design and analysis of spatial filter system in Shenguang Ⅱ facility

ZENG Tai-ying,HUANG Hong-biao,ZHANG Tao,ZHU Jian-qiang
2007-01-01
High Power Laser and Particle Beams
Abstract:Considering the stability requirement of the spatial filter system in ShenguangⅡ facility,a modal test was carried out to analysis the spatial filter system to check its working performance.The key parameters which control the stability system are indicated according to the theory of vibration.Numerical analysis results show that the natural frequency of SF4 system is 83 Hz,and it satisfies the whole facility stability working performance.The adding carriage in system can increase the rigidity and change the modal.For the support table,the tabletop should be separated and the height should be low to more easily control the distortion of the optical elements on top of the table.As a kind of elastic connection,the bellow in the system can absorb the vibration energy to control the system displacement,and the rigidity of connection can be changed by selecting different bellow thickness.All design can be used in other structure systems in Shenguang facility.
What problem does this paper attempt to address?