Investigation on A Thermoacoustically Driven Pulse Tube Cooler Working at 82.5 K

Limin Qiu,Daming Sun,Weilin Yan,Ping Chen,Zhihua Gan,Guobang Chen
DOI: https://doi.org/10.1016/b978-008044559-5/50091-0
2005-01-01
Abstract:It is an efficient way to increase the performance of the thermoacoustic refrigeration system by improving the frequency matching between thermoacoustic engines and pulse tube coolers (PTCs). Investigation on the performance of the refrigeration system under different operating frequency was carried out by changing the length of the resonance straight tube of a thermoacoustic Stirling engine. With working pressure and heating power of 2.8 MPa and 2500 W respectively, the single stage double-inlet PTC reaches the refrigeration temperature of 82.5K at 45 Hz.
What problem does this paper attempt to address?