Volume Kinetics of Ringer Solution in Patients During General Anesthesia Combined with Epidural Blockade

嵇富海,张俊峰,蒋豪,薛张纲,杨建平
DOI: https://doi.org/10.3760/j.issn:0254-1416.2006.10.002
2006-01-01
Abstract:Objective To investigate the distribution and elimination of the fluid infused before and during general anesthesia combined with epidural block using mathematical model of volume kinetics and mass balance. Methods Twenty ASA I or H male patients aged 33-56 yrs weighing 51-77 kg undergoing elective resection of liver cancer were randomly divided into 2 groups ( n = 10 each) : lactated Ringer's solution (RL) 30 ml·kg-1 was infused over 30 min at 60 min before (groupⅠ) or 10 min after (groupⅡ) induction of general anesthesia combined with epidural block with 0.25% bupivacaine 8-10 ml. The patients were unpremedicated. Epidural catheter was placed at T7,8 interspace before induction of general anesthesia and correct placement was confirmed by a test dose of 2 % lidocaine 3-5 ml. Arterial and CVP lines were established before anesthesia and cardiac output (CO), cardiac index (CI) and thoracic water index were measured using 4 electrode impedance cardiogram. General anesthesia was induced with midazolam, thiopental, fentanyl and succinyl choline and maintained with isoflurane and intermittent iv boluses of vecuronium and fentanyl. Blood samples were taken every 5 min during the 90 min after RL 30 ml·kg-1 was infused for determination of Hb and Hct. Hemodynamic parameters and urine output were recorded during the same period. The parameters of volume kinetics included V (target volume), kr (clearance rate) , V1 (central target volume) , V2 ( peripheral target volume) kt(transferal rate) . The parameters of mass balance included volume increase, fluid retained and volume expansion efficacy (VEE). Results The two groups were comparable with respect to M/F ratio, age, body weight and height. MAP, HR, CO and CI at the beginning and the end of and 60 min after the volume expansion were significantly lower than the baseline values before induction of anesthesia in groupⅡand than in groupⅠ( P 0.05) . The volume increase, the percentage of fluid retained and VEE were significantly greater in groupⅡthan in groupⅠ(P 0.05) . The values of V, V1 , V2; kr and kt were significantly higher in groupⅠthan in groupⅡ. The urine output was also significantly greater in groupⅠthan in groupⅡ. Conclusion The efficacy of Ringer's solution for volume expansion is significantly higher when it is infused during anesthesia than before anesthesia.
What problem does this paper attempt to address?