Measurement and Analysis of Phase Transformation Temperature of TC1l Titanium Alloy

Li Yutao,Geng Lin,Xu Bin,Li Aibin,Wang Guisong
DOI: https://doi.org/10.3969/j.issn.0258-7076.2006.02.024
2006-01-01
Abstract:Three methods including the calculation method, differential scanning calorimetry and metallographic techniques were employed to calculate and measure the phase transformation temperature of TC11 titanium alloy. The comparison between the three methods indicates that the theory value obtained by the calculation method approaches the true value, because this method requires that the content of each element in the TC11 alloy is in a certain range. The value obtained by the differential scanning calorimetry method is a little exorbitant, because continuous heating delays the phase transformation. The phase transformation temperature can be measured accurately by the metallographic technique if more quenching temperatures are chosen. In the metallographic method, the microstructure of the samples quenched from different temperatures was observed and the temperature at which the primary α phase disappear was determined, so that the α+β/β transformation temperature of the TC11 titanium alloy is determined to be 1035 ℃. The reason of the difference of phase transformation temperature between different titanium alloys was discussed.
What problem does this paper attempt to address?