Shed Optimized Design of Anti-icing Electrical Locomotive Roof Insulator

Baoqiang Sun,Jingzhou Hou,Liming Wang,Zhicheng Guan
DOI: https://doi.org/10.13336/j.1003-6520.hve.2011.07.019
2011-01-01
Abstract:Most flashover faults of electrical locomotive roof insulators happen from December to February in the next year.A large proportion of these flashover accidents are caused by insulators icing.Therefore,it is important to study the anti-icing technology and development of anti-icing locomotive roof insulator.To rationally design the shed of locomotive roof insulator,we established a three-dimensional two-phase uncompressible turbulent flow field mode.Moreover,using the method of numerical simulation,we analyzed and researched the outer flow field characteristics of locomotive roof insulator and impingement characteristics of liquid particles to insulator.According to the impingement rate,we designed the anti-icing shed shape of roof insulator.We suggested that shed shape should be the inclination of topper surface 8°,the inclination of lower surface 0°,the distance between two adjacent sheds 55 mm,and one-big-one-small shed configuration should be chosen.