Characteristics of Amoxicillin Wastewater Degradation by Electro-Fenton Process

Yu-fang TANG,Ting-ting SHEN,Xiao-ming LI,Qi YANG,Jin-jing LIU,Juan WANG
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2011.05.020
2011-01-01
Abstract:The electro-Fenton process was used to degrade synthetic amoxicillin wastewater.The experimental results show that the electro-Fenton process is superior to ordinary Fenton process in COD removal.This is mainly due to the electrochemical regeneration of Fe2+ at cathode,which can catalyze H2O2.The effects of different factors on COD removal efficiency are analyzed when the initial concentration of amoxicillin wastewater is 0.1 g/L.Under the optimum reaction conditions of H2O2=13 mmol/L,Fe2+ ∶ H2O2=1 ∶ 36,I=0.3 A and pH=4.5,the COD removal rate of 70% and the BOD5/COD ratio of 0.41 are achieved after 100 min treatment.The Fe2+ ∶ H2O2 ratio of 1 ∶ 36 can also be used to degrade amoxicillin wastewater with high concentration.The electrolysis can be controlled at the first 10 min of the reaction time because the degradation of amoxicillin is very fast in this period.
What problem does this paper attempt to address?